13 research outputs found

    A Growing-Season Hydroclimatology, Focusing on Soil Moisture Deficits, for the Ohio Valley Region

    Get PDF
    A hydroclimatology, or description of long-term means and interannual variation, that focuses on soil moisture deficits was constructed for the period of 1895–1998 for a six-state region composing the Ohio Valley. The term ‘‘deficit’’ is considered from an agricultural point of view whereby moisture-induced crop stress is a combination of insufficient precipitation and soil moisture. Of particular concern are deficits that occur during the growing season (May–September) when vegetation is most susceptible to moisture-induced stress. Evidence suggests that there is considerable temporal variability but no long-term trend toward either wetter or drier conditions in the Ohio Valley. The pattern of growing-season deficit is characterized by multiyear and multidecadal cycles of wet and dry periods. Decreases in precipitation during years with anomalously large growing-season deficits, however, are associated more with the reduced frequency of precipitation events than with any changes in intensity. These variations in precipitation frequency and the conditions conducive to droughts are intimately linked with large-scale atmospheric conditions, including the low-level and upper-level flow patterns

    Ethical dilemmas and validity issues related to the use of new cooling technologies and early recognition of exertional heat illness in sport

    Get PDF
    The Tokyo 2020 Olympic Games is expected to be among the hottest Games in modern history, increasing the chances for exertional heat stroke (EHS) incidence, especially in non-acclimatised athletes/workers/spectators. The urgent need to recognise EHS symptoms to protect all attendees'' health has considerably accelerated research examining the most effective cooling strategies and the development of wearable cooling technology and real-time temperature monitoring. While these technological advances will aid the early identification of EHS cases, there are several potential ethical considerations for governing bodies and sports organisers. For example, the impact of recently developed cooling wearables on health and performance is unknown. Concerning improving athletic performance in a hot environment, there is uncertainty about this technology''s availability to all athletes. Furthermore, the real potential to obtain real-time core temperature data will oblige medical teams to make crucial decisions around their athletes continuing their competitions or withdraw. Therefore, the aim of this review is (1) to summarise the practical applications of the most novel cooling strategies/technologies for both safety (of athletes, spectators and workers) and performance purposes, and (2) to inform of the opportunities offered by recent technological developments for the early recognition and diagnosis of EHS. These opportunities are presented alongside several ethical dilemmas that require sports governing bodies to react by regulating the validity of recent technologies and their availability to all

    Heat Safety in the Workplace:Modified Delphi Consensus to Establish Strategies and Resources to Protect U.S Workers

    Get PDF
    The purpose of this consensus document was to develop feasible, evidence‐based occupational heat safety recommendations to protect the US workers that experience heat stress. Heat safety recommendations were created to protect worker health and to avoid productivity losses associated with occupational heat stress. Recommendations were tailored to be utilized by safety managers, industrial hygienists, and the employers who bear responsibility for implementing heat safety plans. An interdisciplinary roundtable comprised of 51 experts was assembled to create a narrative review summarizing current data and gaps in knowledge within eight heat safety topics: (a) heat hygiene, (b) hydration, (c) heat acclimatization, (d) environmental monitoring, (e) physiological monitoring, (f) body cooling, (g) textiles and personal protective gear, and (h) emergency action plan implementation. The consensus‐based recommendations for each topic were created using the Delphi method and evaluated based on scientific evidence, feasibility, and clarity. The current document presents 40 occupational heat safety recommendations across all eight topics. Establishing these recommendations will help organizations and employers create effective heat safety plans for their workplaces, address factors that limit the implementation of heat safety best‐practices and protect worker health and productivity

    Coupling Tritium Release Data with Remotely Sensed Precipitation Data to Assess Model Uncertainties

    Get PDF
    Proceedings of the 2011 Georgia Water Resources Conference, April 11, 12, and 13, 2011, Athens, Georgia.An accidental tritium release (570 L, 210 TBq) from the K-Reactor at the Savannah River Site (South Carolina, USA) occurred between December 22- 25, 1991. Observed tritium concentrations in rivers and streams, as well as in the coastal estuary, are used to calibrate a hydrologic flow and transport model, BASINS 4.0 (Better Assessment Science Integrating Point and Non- Point Sources) environmental analysis system and the HSPF hydrologic model. The model is used to investigate complex hydrometeorological and source attribution problems. Both source and meteorologic input uncertainties are evaluated with respect to model predictions. Meteorological inputs include ground-based rain gauges supple-mented with and several NASA products including TRMM 3B42, TRMM 3B42RT, and MERRA (Modern Era Retrospective-Analysis for Research and Applications) reanalysis data. Model parameter uncertainties are evaluated using PEST (Model-Independent Parameter Estimation and Uncertainty Analysis) and coupled to meteorologic uncertainties to provide bounding estimates of model accuracy.Sponsored by: Georgia Environmental Protection Division U.S. Geological Survey, Georgia Water Science Center U.S. Department of Agriculture, Natural Resources Conservation Service Georgia Institute of Technology, Georgia Water Resources Institute The University of Georgia, Water Resources FacultyThis book was published by Warnell School of Forestry and Natural Resources, The University of Georgia, Athens, Georgia 30602-2152. The views and statements advanced in this publication are solely those of the authors and do not represent official views or policies of The University of Georgia, the U.S. Geological Survey, the Georgia Water Research Institute as authorized by the Water Research Institutes Authorization Act of 1990 (P.L. 101-307) or the other conference sponsors

    Heat Acclimation Following Heat Acclimatization Elicits Additional Physiological Improvements in Male Endurance Athletes

    No full text
    The purpose of this study was to assess the effectiveness of heat acclimatization (HAz) followed by heat acclimation (HA) on physiological adaptations. 25 male endurance athletes (age 36 ± 12 y, height 178.8 ± 6.39 cm, body mass 73.03 ± 8.97 kg, and VO2peak 57.5 ± 7.0 mL·kg−1·min−1) completed HAz and HA. HAz was 3 months of self-directed summer training. In the laboratory, a 5-day HA prescribed exercise to target a hyperthermic zone (HZHA) of Trec between 38.50 and 39.75 °C for 60 min. Exercise trials were 60 min of running (59% ± 2% VO2peak) in an environmental chamber (wet bulb globe temperature 29.53 ± 0.63 °C) and administered at: baseline, post-HAz, and post-HAz+HA. Measured variables included internal body temperature (Trec), heart rate (HR), and sweat rate (SR). Repeated measure ANOVAs and post hoc comparisons were used to assess statistically significant (p < 0.05) differences. Trec was lower post-HAz+HA (38.03 ± 0.39 °C) than post-HAz (38.25 ± 0.42 °C, p = 0.009) and baseline (38.29 ± 0.37 °C, p = 0.005). There were no differences between baseline and post-HAz (p = 0.479) in Trec. HR was lower post-HAz (143 ± 12 bpm, p = 0.002) and post-HAz+HA (134 ± 11 bpm, p < 0.001) than baseline (138 ± 14 bpm). HR was lower post-HAz+HA than post-HAz (p = 0.013). SR was higher post-HAz+HA (1.93 ± 0.47 L·h−1) than post-HAz (1.76 ± 0.43 L·h−1, p = 0.027). Combination HAz and HA increased physiological outcomes above HAz. This method can be used to improve performance and safety in addition to HAz alone
    corecore